F7016. Office buildings, Gross Floor Area (GFA)
F7016. Office buildings, Gross Floor Area (GFA)
Inside wall 0,8 - 1,0 m
2 inside wall / m
2 GFA.
Inside wall finishing: 1,6 - 2,0 m
2 finishing / m
2 GFA.
Main element | Description | Specialty | Price per m2 GFA |
---|---|---|---|
(22) Interior walls / (32) Interior walls openings | Interior wall openings | Masonry | 87,- |
Light glued | 75,- | ||
Metal posts + finish | 70 mm | 50,- | |
100 mm | 58,- | ||
125 mm | 65,- | ||
Demountable system + suwide | Suwide finish | 100,- | |
Steel | 140,- | ||
Glass wall 50% / wall system 50% | 125,- | ||
(42) Interior wall finish | Jointing | Facing brickwork | 9,- |
Plasterwork | 18,- | ||
Decorative plaster | 37,50 | ||
Painting | 13,- | ||
Wallpaper | 18,- | ||
Textile wallcovering | 25,- | ||
(43) Floor finish | Cement deck | With linoleum | 45,- |
With carpet | 41,- | ||
Computer floor | 120,- | ||
Tiled floor | 67,- | ||
(35)/(45) Ceiling finish | Wood carpentry | 97,- | |
System ceiling | Mineral wool | 31,- | |
Aluminum lamellea | 62,- | ||
Integrated | 68,- | ||
(51) Heat generation / (56) Heat distribution | Boiler | VR/HR | 24,- |
(52) Draining | Rainwater drains | 8,- | |
Internal sewer system | 3,- | ||
(53) Water | Cold water installation | 4,- | |
Hot water installation | Decentralized generation | 2,- | |
(56) Heat distribution | Pipes | With induction units | 127,- |
With radiators | 48,- | ||
With convectors | 66,- | ||
(57) Air treatment | Ventilation | Standard | 71,- |
Limited cooling | 149,- | ||
Extensive cooling | 219,- | ||
(61) Central electrical facilities | Safety grounding NEN 1010 | 1,- | |
Cable duct and cable trays | 7,- | ||
Wall conduit | 10,- | ||
Low voltage main distributor | With overvoltage protection | 8,- | |
(62) Power current | Combination junction devices | With supply lines (extensive) | 10,- |
Supply lines for WTB and elevator installations | 3,- | ||
Powerplant | 1,- | ||
(63) Lighting | Lighting fixture | Conventional | 40,- |
High-frequent | 45,- | ||
Combined light and wall outlets end group installation | 2 wall outlets per workplace | 20,- | |
Emergency lighting | Decentral (batteries) | 5,50 | |
(64) Communication | Paging system | 2,- | |
Empty pipe installation for integrated datasystem | Telephone and data | 2,- | |
Integrated datasystem wired | Telephone and data, 3 pc/wp | 23,- | |
(65) Security | Hose reel and fire extinguisher | 3,- | |
Fire alarm and evacuation installation | Escape route detection, limited | 10,- | |
Extensive escape route detection | 18,- | ||
Burglar alarm | Simple | 6,- | |
(67) Building management system | Control and signal system of mechanical and electrical installations | 3,- |