| Main element | Description | Specialty | Price per m2 constructed area | 
|---|---|---|---|
| (11) Ground works | Sod removal and backfilling | 10,- | |
| Soil improvement | 1 m depth | 25,- | |
| 2 m depth | 49,- | ||
| Land fill | height 1 m | 27,- | |
| (13) Floors beds | Ground floor on sand | Thickness 150 mm | 39,50 | 
| Thickness 200 mm | 49,- | ||
| Thickness 250 mm | 59,- | ||
| Insulation layer | Thickness 100 mm | 12,- | |
| Thickness 150 mm | 15,- | ||
| Hollow core slab | Insulated | 88,50 | |
| Combination floor | Insulated | 47,- | |
| (16) Foundation constructions | Concrete beam | 41,50 | |
| Concrete footing | With concrete beam | 51,- | |
| With brick strip | 52,- | ||
| (17) Pile foundations | Concrete pile, prefab | 0 - 2 floors, 10 m | 37,- | 
| 0 - 2 floors, 18 m | 61,- | ||
| 0 - 2 floors, 25 m | 83,50 | ||
| 2 - 4 floors, 10 m | 58,- | ||
| 2 - 4 floors, 18 m | 100,- | ||
| 2 - 4 floors, 25 m | 133,- | ||
| 4 - 6 floors, 10 m | 85,- | ||
| 4 - 6 floors, 18 m | 145,- | ||
| 4 - 6 floors, 25 m | 196,- | ||